How to Choose the Right Tender for Your Sailboat
A good tender should make life on the water easier, not more complicated. Here's what to look for, and why the Walker Bay 10 fits the bill for a lot...
GX Tank 140 is available as a special order — we’ll order it directly from our supplier when you place your order.
Couldn't load pickup availability
✔ Locally owned in Nanaimo, BC
✔ Trusted by boaters and anglers since 1986
✔ Knowledgeable staff with real on-the-water experience
✔ Large in-stock selection of marine & fishing gear
We’re here to help you get the right gear the first time.
We ship across Canada with fast, reliable delivery from our Nanaimo location.
✔ Trusted since 1986
✔ Fast Canada-wide shipping
✔ Expert support available
Need it sooner or have questions? Our team is here to help.
We stand behind the products we sell and want you to shop with confidence.
✔ Easy returns on eligible items
✔ Manufacturer warranties supported
✔ In-store support available if you need help
If something isn’t right, reach out and we’ll make it right.
The GX Tank 140 takes readings from up to four tank level sensors. It is an accessory for our range of GX system monitoring products, of which the Cerbo GX is the most commonly used model.
Tank levels can be read-out locally in the system, see screenshot, as well remotely through our VRM Portal.
The GX Tank is compatible with current senders (4 to 20 mA) as well as voltage senders (0 to 10 V). The connection to the GX Device is via USB, which is also how the GX Tank is powered: no additional power wires required.
Tank sender wiring is kept as simple as possible: two of the four inputs provide a 24 V power supply, to power the sender. The other two channels do require an external power supply, and there is a power in terminal together with fused outputs to facilitate that.
Upper and lower limits are configurable, to allow using senders that provide only part of the scale, for example 0 to 5 V.
To provide a stable reading, the readings are averaged damping. The damping can be configured between 1 and 60 seconds.
Faulty sensors and wiring issues are detected: an alarm will be raised when values are out of range.